Customization: | Available |
---|---|
Application: | Hospital, Parking, Warehouse, Hotel, Company, Garage, Community |
Transport Package: | Neutral Packing |
Still deciding? Get samples of US$ 28.5/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Parameter | Parameter Description |
S4A Model | PD-232 |
Product Name | Double Vehicle Loop Detector |
Tuning | Fully automatic |
Self-tuning range | 50 to 1000μH |
Sensitivity | Four step switch selectable |
Frequency | Four step switch selectable Frequency dependent on loop size |
Modes | Output relays operate in the Presence ( fail-secure ), Pulse or Direction logic modes |
Presence Time | Switch selectable Limited presence Permanent presence |
Pulse Output Duration | 500 millisecond options |
Response Times | 20 milliseconds |
Visual Indication | 1 x Power LED - Red 2 x Channel Status LED - Green |
Relay Outputs | 2 x Relays rated - 5A @ 230 VAC |
Reset | Reset by push button on front of enclosure |
Power requirements | 12 - 24V AC/DC ± 15% ( PD-230 ) 120V AC ± 15% ( 50 to 60Hz ) ( PD-231 ) 230V AC ± 15% ( 50 to 60Hz ) ( PD-232 ) |
Operating Temperature | -40°C to +85°C |
Mounting Position | Shelf or DIN rail mounting |