Product Highlights

  • Wide Voltage Compatibility: Supports 230V AC, 115V AC, 24V DC/AC, and 12V DC/AC for global use.
  • Adjustable Sensitivity: Four sensitivity increments allow precise detection tuning via DIP switches.
  • Anti-Interference Filter: Built-in filter mode reduces sensitivity and delays reaction time to eliminate noise.
  • Automatic Sensitivity Boost: Boosts sensitivity to maximum upon vehicle detection for reliable performance.
  • Flexible Relay Output: Configurable relay logic via DIP7 for standard or delayed output modes.
  • CE Certified Quality: Meets CE certification standards for safety and performance in traffic systems.
  • Compact Housing Design: Small size (78x40x108mm) allows easy installation near loops in various settings.

Product Images of Loop Detector for Parking Management Systems-Vehicle Detector

Loop Detector for Parking Management Systems-Vehicle Detector pictures & photos
Loop Detector for Parking Management Systems-Vehicle Detector
Loop Detector for Parking Management Systems-Vehicle Detector pictures & photos
Loop Detector for Parking Management Systems-Vehicle Detector
Loop Detector for Parking Management Systems-Vehicle Detector pictures & photos
Loop Detector for Parking Management Systems-Vehicle Detector
Loop Detector for Parking Management Systems-Vehicle Detector pictures & photos
Loop Detector for Parking Management Systems-Vehicle Detector
Loop Detector for Parking Management Systems-Vehicle Detector pictures & photos
Loop Detector for Parking Management Systems-Vehicle Detector
  • Loop Detector for Parking Management Systems-Vehicle Detector
    Loop Detector for Parking Management Systems-Vehicle Detector
  • Loop Detector for Parking Management Systems-Vehicle Detector
    Loop Detector for Parking Management Systems-Vehicle Detector
  • Loop Detector for Parking Management Systems-Vehicle Detector
    Loop Detector for Parking Management Systems-Vehicle Detector
  • Loop Detector for Parking Management Systems-Vehicle Detector
    Loop Detector for Parking Management Systems-Vehicle Detector
  • Loop Detector for Parking Management Systems-Vehicle Detector
    Loop Detector for Parking Management Systems-Vehicle Detector

Find Similar Products

Product Description

PD-132 Inductive Vehicle Single Loop Detector for Automatic Gate opener barrier gate Traffic Inductive Vehicle access

Leave a message to us, if you need DC12V/DC24V/AC110V,no message send AC220V

Install Detector

The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10mm (mustn't fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as "Loop installation guide").

 
Supply voltage 230V AC, 115V AC, 24V DC/AC, 12V DC/AC (See the label on the detector)
Voltage tolerance AC +10% / -15%
Voltage tolerance DC ±15%
Power Consumption 4.5VA
Output relays 240V/5A
Operating temperature -20ºC ~ 65ºC
Storage temperature -40ºC ~ 85ºC
Frequency range 20 KHz ~ 170 KHz
Reaction time 10ms
Signal holding time Unlimited / limited when loop is permanently covered 10 minutes
Sensitivity Adjustable in 4 increments
Loop inductance Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH
Loop connection wiring Maximum length 20 meters, twisted at least 20 times per meter
Size of Housing L78 x W40 x H108mm

Operation and Indication

While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds, then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault is self-healing the detector will continue to operate.The green channel LED will also glow whenever a vehicle is detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the unit is powered.

Frequency

To eliminate interference of two neighbouring wire loops or loop detectors, the frequency can be altered.

Sensitivity

The sensitivity of the detector allows the detector to be selective as to the change of inductance necessary to produce an output. There are four sensitivity selections and are set as follows by DIP3 and DIP4 Switch.

Automatic Sensitivity Boost

Automatic sensitivity boost is selected by DIP5 switch on the front of the enclosure and is set
as follows: OFF - Disabled, ON - Enabled.
Automatic sensitivity boost causes the sensitivity to be boosted to a maximum on detection
on the vehicle, and maintained at this level during the presence of the vehicle over the loop. When
the vehicle departs the loop and detection is lost the sensitivity reverts to the pre-selected level.

Loop Detector for Parking Management Systems-Vehicle Detector
Filter
 
To eliminate interference of the bad environment, the filter mode is activated by setting the DIP6 Switch to "ON" site. In this mode, the reaction time of the detector is delayed, and the sensitivity is reduced. Usually, the filter mode is disabled by setting the DIP6 Switch to "OFF" site.
Attention ] If the detector isn't working normally, you must check the loop and wiring at first, and then alter the frequency or the sensitivity. At last, try to set it to filter mode.
 
Output Relay
 
If DIP7 is "OFF" site, when a vehicle is detected passing over the inductive loop, the relay1 and relay2 are energized; When the vehicle is detected departing the loop, the relay1 and relay2 are de-energized.If DIP7 is "ON" site, when a vehicle is detected passing over the loop, the relay2 is energized;When the vehicle is detected departing the loop, relay2 is de-energized , and delay 500 ms, the relay1 is energized for 500 ms.
 
Presence Time
 
The presence time may be set to permanent presence or to limited presence. In permanent presence mode the detector will continuously compensate for all environmental changes whilst there is a vehicle present over the loop, the presence mode is set with DIP8 Switch and is
configured as follows: OFF:Limited Presence ( 10 minutes), ON:Permanent Presence
 
Reset Switch
 
The detector automatically tunes to the inductive loop connected to it when the power is applied, whether on initial installation or after any break in power supply. Should it be necessary to retune the detector, as may be required after changing any of the switches or after moving the detector from one installation to another, momentary operation of the RESET switch will initiate the automatic tuning cycle.


Loop Detector for Parking Management Systems-Vehicle Detector
Loop Detector for Parking Management Systems-Vehicle Detector
Loop Detector for Parking Management Systems-Vehicle Detector
Loop Detector for Parking Management Systems-Vehicle Detector
Loop Detector for Parking Management Systems-Vehicle Detector
Loop Detector for Parking Management Systems-Vehicle Detector
Loop Detector for Parking Management Systems-Vehicle Detector
 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR212966". Items marked "verified" are certified.

Watch Video
Watch Video
S4A Industrial Co., Limited
S4A Industrial Co., Limited
S4A Industrial Co., Limited
S4A Industrial Co., Limited
S4A Industrial Co., Limited
S4A Industrial Co., Limited
S4A Industrial Co., Limited
S4A Industrial Co., Limited

About Our Factory & Business Background

Address
The 2nd Floor, Jinmin'an Industrial Zone, #529, Bulong Rd. Bantian St. Longgang Dist, Shenzhen, Guangdong, China
Terms of Payment
T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
EXW
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Yantian, Shekou, Chiwan

Our Production Capability & Technical Expertise

Main Products
Access Control, Electromagnetic Lock, UHF Long Range Reader, RFID Access Control, Em Lock, Automatic Swing Door Opener, Frameless Bolt Lock, Glass Door Lock, Power Supply Controller, Access Exit Push Button

Our Industry Experience & Global Business Record

Export Year
2010-10-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What voltage options are supported?
The detector supports 230V AC, 115V AC, 24V DC/AC, and 12V DC/AC.
How is sensitivity adjusted?
Sensitivity is adjustable in 4 increments using DIP3 and DIP4 switches.
What is the function of the filter mode?
Filter mode eliminates interference by reducing sensitivity and delaying reaction time.
Can the relay output be configured?
Yes, DIP7 allows configuration for standard or delayed relay output modes.
How does the detector handle loop faults?
The Channel LED flashes to indicate a fault; check loop and wiring first.
What is the maximum loop wiring length?
The maximum loop connection wiring length is 20 meters, twisted at least 20 times per meter.
How is the detector reset or retuned?
Press the RESET switch to initiate automatic tuning after power application or changes.